ZEUS 576-ch Recorder & Stimulator
Programmable, Scalable , Single-Box Solution

Zeus Neurophysiology System

Picture
Zeus Brochure (v1.05)
File Size: 414 kb
File Type: pdf
Download File

Zeus is a high-performance, scalable neural data acquisition (DAQ) system for in vivo, extracellular neurophysiology using up to 512 recording electrodes. Optional plug-in modules provide an additional 64 electrode channels for programmable recording & stimulation applications; built-in artifact-rejection circuitry ensure fast recovery of recording channels after stimulation. Zeus's user-friendly software and plug & play hardware provide scientists and engineers with a sophisticated yet easy-to-use neurophysiology system. The Zeus Digital Signal Processor (DSP) and Software acquires, processes, and analyzes physiological signals (e.g., spikes, field potentials, EMG) together with experimental events from third-party equipment including behavior, electrical & optical stimulation (optogenetics), and video systems. Zeus is a cost-effective solution even for high-channel configurations. Price, performance and functionality make it the preferred choice by investigators in academia, industry, and research institutes around the world. 
Request Info or Quote

​Applications

Extracellular neurophysiology
Basic neuroscience
Brain-machine interfaces (BMIs)
Brain-computer interfaces (BCIs)
Neuroprosthetics
​

Accessories:
​NeuroExplorer (data analysis)
​
​Related:
Apollo I 32-ch Recorder
Apollo II 64-ch Recorder​

  • Ultra-compact design​​
  • 512 electrodes (recording)
  • 64 electrodes (stimulation & recording)
  • Per-channel digital filters
  • Built-in electrical stimulators
  • Single units & field potentials
  • I/O for viewing & synchronization
              -32 event channels
              -32 auxiliary analog inputs
              -16 digital outputs
              -Stereo audio output
  • Data access & closed-loop control
              -Low latency
              -Real time
  • Selectable power​​
              -Battery (line-noise immunity)
              -High-isolation AC to DC
Picture
Picture
  • ​Neuropixels probe interface (Fall 2019)​
  • User-friendly interface
  • Multi-channel signal displays
  • Spike sorting (templates, PCA clusters)
  • Manual & auto spike sorting
  • Steretrode & tetrode support
  • Multiple data-file formats
  • MATLAB SDK
  • Flexible I/O control
  • Programmable recording & stimulation
  • Fast artifact-rejection circuity
  • Compatible with
             -NeuroExplorer (Nex Technologies)
             -Spike 2 (CED)
             -Offline Sorter (Plexon)
​Ultimate Headstages
Zeus's digital headstages provide a miniature, featherweight high-fidelity link to electrodes implanted in in vivo brain preparations for electrophysiology studies.The onboard analog filters and digital circuitry combined with LVDS (low voltage, differential signaling) cable transmission ensure a stable, extremely-high, signal-to-noise link to the brain. The multiplexed output allows just a few wires to carry signals from 100’s of electrodes making it ideally suited for recording from freely-behaving animals as small as song birds and baby mice. Expensive and noisy motorized commutators are no longer required.  The headstage is compatible with individual microelectrodes, microwire & microelectrode arrays, silicon probes, and ECoG/iEEG grids. 

Note: Our headstages are compatible with wireless (untethered) devices from TBSI (a division of Harvard Bioscience) and can be used as plug & play (drop in) replacements for the larger headstages in DAQ systems provided by Open Ephys and Intan Technologies.​
Digital Headstages
Picture
32-ch Digital Headstage
Picture
16-ch Digital Headstage
​​​

​
  • Miniature size
  • Ultra lightweight​ (16 ch < 0.6 g / 32 ch < 0.8 g)
  • 16/32/64/128/256 channels
  • High-resolution sampling (30 kHz, 16 bits)
  • Wideband recording (spikes and field potentials)
  • Fast stimulus-artifact suppression & recovery
  • Multiplexed output
  • Low-Voltage Differential-Signaling (LVDS) cable
  • In situ impedance measurement
  • 3-axis accelerometer for position tracking
  • Immunity to environmental noise ​

​Accessories

Headstage Cables
We offer a variety of headstage cables: ultra lightweight cables for recording from small, behaving subjects such as birds & mice and more robust cables with bite-resistant or torque-transmission (commutator) wraps are available upon request. Cable lengths available up to 10 m.  
Picture
                       Primate                                                 Rodent                                      HDMI Cable Extender
Adaptors, Miscellaneous Cables & Interface Panels
Bio-Signal Technologies offers adaptors, cables, and interface panels for interfacing to 3rd-party electrodes, video and control systems. We can also build custom adaptors and cables to meet your needs.
Picture
                                               Omnetics to Samtec                                                          Omnetics to NeuroNexus
Picture
                     Auxiliary Analog                                     TTL Control Events                                  Ground Wires
Commutators: Electrical, Optical & Fluid Channels
Commutators are critical for minimizing mechanical forces on animals and preventing damage to electrical, optical and fluid channels during freely-behaving animal experiments. We offer a variety of commutators with electrical, optical, and fluid channels. We also build noise-immune interfaces to any 3rd-party commutator.  
Picture
                                     Low Cost                                      Low Torque                              Hybrid (electrical + light)

Request Info or Quote

Powered by Create your own unique website with customizable templates.
  • HOME
    • Neurophysiology >
      • Apollo: 32-ch Recording
      • Apollo II: 64-ch Recording >
        • About Us
      • Zeus: 512-ch Recording & 64-ch Stimulation
      • Poseidon: 32-ch Recording
      • Company >
        • Team
        • Mission
      • Neural Interfaces: Electrodes
      • NeuroExplorer: Data Analysis
  • Eye Tracker
  • Contact Us
    • Sales
    • Support